Omniplus dot buses
  Abbreviations

OBD - Onboard diagnostics
WABCO ATR-E (ATC)
 
The following describes the possible current and stored faults for Addresses 7, 8, A, E and F.
 
 
Address 7
Current fault: Meaning of the fault code
  Possible current fault:
  FC   ECU pin number   Fault description
  30   13   Compartment sensor front
  50   12   Temperature sensor on air outlet wall heater bottom front right
  60   25   Temperature sensor on air outlet wall heater bottom left side
  80   5/17   Water valve wall heater bottom left front
  85   4/16   Water valve, wall heater bottom front right
 
 
Stored fault: Meaning of bar indication
 
  Possible stored faults (missing segment in bar indication, for example see picture):
  Segment   ECU pin number   Fault description
  16   13   Compartment sensor front
  12   12   Temperature sensor on air outlet wall heater bottom front right
  10   25   Temperature sensor on air outlet wall heater bottom left side
  6   5/17   Water valve wall heater bottom left front
  5   4/16   Water valve, wall heater bottom front right

 
 
Address 8
Current fault: Meaning of the fault code
  Possible current fault:
  FC   ECU pin number   Fault description
  30   13   Compartment sensor rear
  40   3   Switched output, fresh air ventilation valves
  45   2   Switched output, air mixture ventilation
  50   12   Temperature sensor on air outlet, roof, left
  55   11   Icing sensor (only for climate control system)
  60   25   Temperature sensor on air outlet, roof, right
  80   5/17   Water valve, roof, right
  85   4/16   Water valve, roof, left
 
 
Stored fault: Meaning of bar indication
 
  Possible stored faults (missing segment in bar indication, for example see picture):
  Segment   ECU pin number   Fault description
  16   13   Compartment sensor rear
  14   3   Switched output, fresh air ventilation valves
  13   2   Switched output, air mixture ventilation
  12   12   Temperature sensor on air outlet, roof, left
  11   11   Icing sensor (only for climate control system)
  10   25   Temperature sensor on air outlet, roof, right
  6   5/17   Water valve, roof, right
  5   4/16   Water valve, roof, left

 
 
Address F
Current fault: Meaning of the fault code
  Possible current fault:
  FC   ECU pin number   Fault description
  35   23   Coolant temperature sensor (for water heater)
  40   3   Switched output, condenser blower
  45   2   Switched output, compressor coupling
  50   12   Temperature sensor on air outlet wall heater bottom rear right
  60   25   Temperature sensor on wall heater air outlet
  80   5/17   Water valve, middle bottom right
  85   4/16   Water valve, wall heater bottom rear right
 
 
Stored fault: Meaning of bar indication
 
  Possible stored faults (missing segment in bar indication, for example see picture):
  Segment   ECU pin number   Fault description
  15   23   Coolant temperature sensor (for water heater)
  14   3   Switched output, condenser blower
  13   2   Switched output, compressor coupling
  12   12   Temperature sensor on air outlet wall heater bottom rear right
  10   25   Temperature sensor on wall heater air outlet
  6   5/17   Water valve, middle bottom right
  5   4/16   Water valve, wall heater bottom rear right

 
 
Address E
Current fault: Meaning of the fault code
  Possible current fault:
  FC   ECU pin number   Fault description
  10   --   Checksum fault in EEPROM
  35   21   Water heater: Economy control line
  40   3/4   Motor actuator, air volume, windscreen
  45   5/6   Motor actuator, air volume, footwell
  50   7/8   Motor actuator, bleed valve
  55   22/23   Switched output, fresh air/recirculation valves
  60   13/20   Water heater
  75   35   Air outlet temperature sensor, driver's seat: Short circuit or open circuit
  80   24/25   Driver's seat water valve
  85   34   Outside temperature sensor:
  90   15/26   Water pump heating
 
 
Stored fault: Meaning of bar indication
 
  Possible stored faults (missing segment in bar indication, for example see picture):
  Segment   ECU pin number   Fault description
  9   --   Checksum fault in EEPROM
  7   21   Water heater: Economy control line
  6   3/4   Motor actuator, air volume, windscreen
  5   5/6   Motor actuator, air volume, footwell
  4   7/8   Motor actuator, bleed valve
  3   22/23   Switched output, fresh air/recirculation valves
  2   13/20   Water heater
  15   35   Air outlet temperature sensor, driver's seat: Open circuit
  10   24/25   Driver's seat water valve
  13   34   Outside temperature sensor:
  12   15/26   Water pump heating
  16   35   Air outlet temperature sensor, driver's seat: Short circuit

 
 
Address F
Current fault: Meaning of the fault code
  Possible current fault:
  FC   ECU pin number   Fault description
  11   21...26   Broken lead/missing load on final stage group 1
  12   21...26   Plus terminal on final stage group 1
  13   21...26   Earth terminal on final stage group 1
  14   21...26   Bridge terminal on final stage group 1
  21   3...8   Broken lead/missing load on final stage group 2
  22   3...8   Plus terminal on final stage group 2
  23   3...8   Earth terminal on final stage group 2
  24   3...8   Bridge terminal on final stage group 2
  90   17   Cooling system: Low pressure fault
  91   11 Address A   Cooling system: High pressure fault
  96   29   Control unit with address 7 without communication
  97   29   Control unit with address 8 without communication
  99   29   Control unit with address A without communication
 
 
Stored fault: Meaning of bar indication
 
  Possible stored faults (missing segment in bar indication, for example see picture):
  Segment   ECU pin number   Fault description
  5   17   Cooling system: Low pressure fault
  6   11 Address A   Cooling system: High pressure fault
  1   29   Control unit with address 7 without communication
  2   29   Control unit with address 8 without communication
  4   29   Control unit with address A without communication