OBD - Onboard diagnostics |
| WABCO ATR driver's position (ATC) |
| |
|
|
Current fault: Meaning of the fault code |
|
|
|
|
Possible current fault: |
|
FC |
|
ECU pin number |
|
Fault description |
|
210 |
|
-- |
|
EEPROM data checksum fault |
|
95 |
|
2 |
|
Main water valve: Earth terminal |
|
90 |
|
15, 26 |
|
Water pump: Plus terminal, implausibility in readback1 |
|
85 |
|
34 |
|
Outside temperature sensor: Plus terminal, earth terminal or outside range |
|
80 |
|
24, 25 |
|
Water valve: Open circuit, short circuit, earth terminal or plus terminal |
|
75 |
|
35 |
|
Air outlet temperature sensor: Plus terminal, earth terminal or outside range |
|
65 |
|
14 |
|
Tacho signal |
|
60 |
|
13, 20, 21 |
|
Supplementary heating: Earth terminal, open circuit |
|
55 |
|
17, 22, 23 |
|
Fresh air/recirculation valve: Open circuit, short circuit, earth terminal or plus terminal |
|
50 |
|
7, 8, 33 |
|
Fresh air valve: Open circuit, short circuit, earth terminal or plus terminal |
|
45 |
|
5, 6, 16 |
|
Footwell valve: Open circuit, short circuit, earth terminal or plus terminal |
|
40 |
|
3, 4, 32 |
|
Front screen valve: Open circuit, short circuit, earth terminal or plus terminal |
|
| |
|
|
Stored fault: Meaning of bar indication |
|
|
|
|
Possible stored faults (missing segment in bar indication, for example see picture): |
|
|
Segment |
|
ECU pin number |
|
Fault description |
|
1 |
|
-- |
|
EEPROM data checksum fault |
|
3 |
|
2 |
|
Main water valve: Earth terminal |
|
4 |
|
15, 26 |
|
Water pump: Plus terminal, implausibility in readback1 |
|
5 |
|
34 |
|
Outside temperature sensor: Plus terminal, earth terminal or outside range |
|
6 |
|
24, 25 |
|
Water valve: Open circuit, short circuit, earth terminal or plus terminal |
|
7 |
|
35 |
|
Air outlet temperature sensor: Plus terminal, earth terminal or outside range |
|
9 |
|
14 |
|
Tacho signal |
|
10 |
|
13, 20, 21 |
|
Supplementary heating: Earth terminal, open circuit |
|
11 |
|
17, 22, 23 |
|
Fresh air/recirculation valve: Open circuit, short circuit, earth terminal or plus terminal |
|
12 |
|
7, 8, 33 |
|
Fresh air valve: Open circuit, short circuit, earth terminal or plus terminal |
|
13 |
|
5, 6, 16 |
|
Footwell valve: Open circuit, short circuit, earth terminal or plus terminal |
|
14 |
|
3, 4, 32 |
|
Front screen valve: Open circuit, short circuit, earth terminal or plus terminal |
|
|
| 1 The control unit receives the message "water pump running" although the water pump relay is not controlled. This can be caused by a sticking relay contact. |