FE |
0001 |
Rectifier part of traction motor:Temperature sensor is faulty. |
FE |
0002 |
Rectifier part of traction motor:Excess temperature at heat sink (> 85 °C) |
FE |
0004 |
Rectifier part of traction motor:Excess temperature at controller hardware |
FE |
0006 |
Rectifier part of traction motor:Excess temperature at cable semiconductor |
FE |
0007 |
Rectifier part of traction motor:Temperature sensors faulty(Path 00 - 10) |
FE |
0011 |
Rectifier part of traction motor:CAN controller was too often in Bus OFF state. |
FE |
0020 |
Rectifier part of traction motor:The actuation element of the brake resistor is faulty.(The 24 V supply may be faulty.) |
FE |
0021 |
Rectifier part of traction motor:The actuation element of the rectifier is faulty.(The 24 V supply may be faulty.) |
FE |
0022 |
Rectifier part of traction motor:Overvoltage |
FE |
0023 |
Rectifier part of traction motor:Undervoltage |
FE |
0024 |
Rectifier part of traction motor:Excess current |
FE |
0025 |
Rectifier part of traction motor:Short circuit |
FE |
0026 |
Rectifier part of traction motor:Current detection fault at traction motor |
FE |
0030 |
Rectifier part of traction motor:15 V supply is not within the permissible range. |
FE |
0031 |
Rectifier part of traction motor:EEPROM error |
FE |
0032 |
Rectifier part of traction motor:Fault when reading the EEPROM |
FE |
0033 |
Rectifier part of traction motor:Fault when writing the EEPROM |
FE |
0034 |
Rectifier part of traction motor:EEPROM does not respond to the slave address. |
FE |
0035 |
Rectifier part of traction motor:The write access to EEPROM takes place without logon. |
FE |
0037 |
Rectifier part of traction motor:Checksum error when block reading the EEPROM |
FE |
0038 |
Rectifier part of traction motor:Checksum error in the case of the SIADIS parameters |
FE |
0039 |
Rectifier part of traction motor:RAM test was unsuccessful. |
FE |
0040 |
Rectifier part of traction motor:The fault memory of the FE Drive electronics control module is faulty. |
FE |
0041 |
Rectifier part of traction motor:Fault in the programmable logic element |
FE |
0042 |
Rectifier part of traction motor:Flash checksum error |
FE |
0043 |
Rectifier part of traction motor:High speed link between the two rectifiers is faulty. |
FE |
0044 |
Rectifier part of traction motor:24 V supply is not within the permissible range. |
FE |
0050 |
Rectifier part of traction motor:Time monitoring error in program run |
FE |
0051 |
Rectifier part of traction motor:Illegal software command |
FE |
0052 |
Rectifier part of traction motor:Stack overflow |
FE |
0053 |
Rectifier part of traction motor:Overflow in the 1ms time slice |
FE |
0054 |
Rectifier part of traction motor:Overflow in the 10ms time slice |
FE |
0055 |
Rectifier part of traction motor:Overflow in the 100ms time slice |
FE |
0076 |
Rectifier part of traction motor:Unrectifiable rectifier shutoff |
FE |
0099 |
Rectifier part of traction motor:General system error |
FE |
1001 |
Rectifier part of generator:Temperature sensor is faulty. |
FE |
1002 |
Rectifier part of generator:Excess temperature at heat sink (> 85 °C) |
FE |
1004 |
Rectifier part of generator:Excess temperature at controller hardware |
FE |
1006 |
Rectifier part of generator:Excess temperature at cable semiconductor |
FE |
1007 |
Rectifier part of generator:Temperature sensors faulty(Path 00 - 10) |
FE |
1011 |
Rectifier part of generator:CAN controller was too often in Bus OFF state. |
FE |
1020 |
Rectifier part of generator:The actuation element of the brake resistor is faulty.(The 24 V supply may be faulty.) |
FE |
1021 |
Rectifier part of generator:The actuation element of the rectifier is faulty.(The 24 V supply may be faulty.) |
FE |
1022 |
Rectifier part of generator:Overvoltage |
FE |
1023 |
Rectifier part of generator:Undervoltage |
FE |
1024 |
Rectifier part of generator:Excess current |
FE |
1025 |
Rectifier part of generator:Short circuit |
FE |
1026 |
Rectifier part of generator:Current detection fault at generator |
FE |
1030 |
Rectifier part of generator:15 V supply is not within the permissible range. |
FE |
1031 |
Rectifier part of generator:EEPROM error |
FE |
1032 |
Rectifier part of generator:Fault when reading the EEPROM |
FE |
1033 |
Rectifier part of generator:Fault when writing the EEPROM |
FE |
1034 |
Rectifier part of generator:EEPROM does not respond to the slave address. |
FE |
1035 |
Rectifier part of generator:The write access to EEPROM takes place without logon. |
FE |
1037 |
Rectifier part of generator:Checksum error when block reading the EEPROM |
FE |
1038 |
Rectifier part of generator:Checksum error in the case of the SIADIS parameters |
FE |
1039 |
Rectifier part of generator:RAM test was unsuccessful. |
FE |
1040 |
Rectifier part of generator:The fault memory of the FE Drive electronics control module is faulty. |
FE |
1041 |
Rectifier part of generator:Fault in the programmable logic element |
FE |
1042 |
Rectifier part of generator:Flash checksum error |
FE |
1043 |
Rectifier part of generator:High speed link between the two rectifiers is faulty. |
FE |
1044 |
Rectifier part of generator:24 V supply is not within the permissible range. |
FE |
1050 |
Rectifier part of generator:Time monitoring error in program run |
FE |
1051 |
Rectifier part of generator:Illegal software command |
FE |
1052 |
Rectifier part of generator:Stack overflow |
FE |
1053 |
Rectifier part of generator:Overflow in the 1ms time slice |
FE |
1054 |
Rectifier part of generator:Overflow in the 10ms time slice |
FE |
1055 |
Rectifier part of generator:Overflow in the 100ms time slice |
FE |
1071 |
Rectifier part of generator:Signals from the DNR pushbutton switch are internally wrongly transmitted. |
FE |
1076 |
Rectifier part of generator:Unrectifiable rectifier shutoff |
FE |
1099 |
Rectifier part of generator:General system error |
FE |
2001 |
Generator:Temperature sensor is faulty. |
FE |
2005 |
Generator:Excess temperature (possible failure of current limiter) |
FE |
2075 |
Generator:Engine overspeed |
FE |
3001 |
Engine:Temperature sensor is faulty. |
FE |
3005 |
Engine:Excess temperature (possible failure of current limiter) |
FE |
3074 |
Engine:Rotary sensor fault |
FE |
3075 |
Engine:Engine overspeed |
FE |
4001 |
Brake resistor:Temperature sensor is faulty. |
FE |
4003 |
Brake resistor:Excess temperature at braking resistor |
FE |
4072 |
Brake resistor:Resistance is too high.(Cable break) |
FE |
4073 |
Brake resistor:Resistance is too low.(Short circuit) |
FE |
5070 |
DNR pushbutton:Signal read in from DNR pushbutton is implausible. |
FE |
6010 |
NOT ASSIGNABLE:No CAN values received for excessively long time |
FE |
6011 |
NOT ASSIGNABLE:CAN controller was too often in Bus OFF state. |
FE |
6060 |
NOT ASSIGNABLE:Backup processor is not active. |
FE |
6061 |
NOT ASSIGNABLE:The drive status is within the forbidden quadrant. |
FE |
6062 |
NOT ASSIGNABLE:The 'DRIVE' specified status is not maintained. |
FE |
6063 |
NOT ASSIGNABLE:The 'BRAKE' specified status is not maintained. |
FE |
6064 |
NOT ASSIGNABLE:Implausible accelerator pedal set value |
FE |
6065 |
NOT ASSIGNABLE:Implausible brake pedal set value |
FE |
6066 |
NOT ASSIGNABLE:The specified status IDLE SPEED is not maintained. |
FE |
6067 |
NOT ASSIGNABLE:Unauthorized crawling |
FE |
6068 |
NOT ASSIGNABLE:Safety relay jamming. |
FE |
6071 |
NOT ASSIGNABLE:Signals from the DNR pushbutton switch are internally wrongly transmitted. |