DV 3


MTS MW01 -- -- Learned number of doors
MTS MW11 -- mV Operating voltage of control module
MTS MW12 -- mV Voltage at solenoid valves
MTS MW13 -- mV Door reference voltage
MTS MW14 -- mV Learned door limit value 'closed' at front
MTS MW15 -- mV Learned door limit value 'open' at front
MTS MW16 -- mV Learned door limit value 'closed' at rear
MTS MW17 -- mV Learned door limit value 'open' at rear
MTS MW18 -- -- Learned pulse count for complete front door operation running
MTS MW19 -- -- Learned pulse count for complete rear door operation running
MTS MW20 -- % Position of front door
MTS MW21 -- % Position of rear door
MTS MW22 -- -- Last door operation
MTS MW23 -- -- Last pinch detection
MTS MW31 -- mV Operating voltage of control module
MTS MW32 -- mV Voltage at solenoid valves
MTS MW33 -- mV Door reference voltage
MTS MW34 -- mV Learned door limit value 'closed' at front
MTS MW35 -- mV Learned door limit value 'open' at front
MTS MW36 -- mV Learned door limit value 'closed' at rear
MTS MW37 -- mV Learned door limit value 'open' at rear
MTS MW38 -- -- Learned pulse count for complete front door operation running
MTS MW39 -- -- Learned pulse count for complete rear door operation running
MTS MW40 -- % Position of front door
MTS MW41 -- % Position of rear door
MTS MW42 -- -- Last door operation
MTS MW43 -- -- Last pinch detection
MTS MW51 -- mV Operating voltage of control module
MTS MW52 -- mV Voltage at solenoid valves
MTS MW53 -- mV Door reference voltage
MTS MW54 -- mV Learned door limit value 'closed' at front
MTS MW55 -- mV Learned door limit value 'open' at front
MTS MW56 -- mV Learned door limit value 'closed' at rear
MTS MW57 -- mV Learned door limit value 'open' at rear
MTS MW58 -- -- Learned pulse count for complete front door operation running
MTS MW59 -- -- Learned pulse count for complete rear door operation running
MTS MW60 -- % Position of front door
MTS MW61 -- % Position of rear door
MTS MW62 -- -- Last door operation
MTS MW63 -- -- Last pinch detection
MTS MW71 -- mV Operating voltage of control module
MTS MW72 -- mV Voltage at solenoid valves
MTS MW73 -- mV Door reference voltage
MTS MW74 -- mV Learned door limit value 'closed' at front
MTS MW75 -- mV Learned door limit value 'open' at front
MTS MW76 -- mV Learned door limit value 'closed' at rear
MTS MW77 -- mV Learned door limit value 'open' at rear
MTS MW78 -- -- Learned pulse count for complete front door operation running
MTS MW79 -- -- Learned pulse count for complete rear door operation running
MTS MW80 -- % Position of front door
MTS MW81 -- % Position of rear door
MTS MW82 -- -- Last door operation
MTS MW83 -- -- Last pinch detection
MTS MW91 -- mV Operating voltage of control module
MTS MW92 -- mV Voltage at solenoid valves
MTS MW93 -- mV Door reference voltage
MTS MW94 -- mV Learned door limit value 'closed' at front
MTS MW95 -- mV Learned door limit value 'open' at front
MTS MW96 -- mV Learned door limit value 'closed' at rear
MTS MW97 -- mV Learned door limit value 'open' at rear
MTS MW98 -- -- Learned pulse count for complete front door operation running
MTS MW99 -- -- Learned pulse count for complete rear door operation running
MTS MW100 -- % Position of front door
MTS MW101 -- % Position of rear door
MTS MW102 -- -- Last door operation
MTS MW103 -- -- Last pinch detection
MTS BW01 01 -- C3 signal 'vehicle moving'
MTS BW02 01 Aktiv / Nicht Aktiv Ignition
MTS BW02 23 Aktiv / Nicht Aktiv 'Switch off frequent stop brake' signal
MTS BW02 45 Aktiv / Nicht Aktiv Entrance lighting enable
MTS BW02 67 Aktiv / Nicht Aktiv 'Cancel door enable' pushbutton
MTS BW03 01 Schalter Offen / Geschlossen 'Block rear door' switch
MTS BW03 23 Schalter Offen / Geschlossen 'Block front door' switch
MTS BW03 45 Schalter Offen / Geschlossen 'Cancel pram function' pushbutton
MTS BW03 67 Schalter Offen / Geschlossen 'Set door enable' pushbutton
MTS BW04 01 Taster Offen / Geschlossen Driver pushbutton
MTS BW04 23 Taster Offen / Geschlossen Stop request pushbutton
MTS BW04 45 Taster Offen / Geschlossen Pram pushbutton
MTS BW04 67 Türlauf nicht verhindert / Verhindert Door blocking
MTS BW05 01 Taster Offen / Geschlossen Driver pushbutton
MTS BW05 23 Taster Offen / Geschlossen Stop request pushbutton
MTS BW05 45 Taster Offen / Geschlossen Pram pushbutton
MTS BW05 67 Türlauf nicht verhindert / Verhindert Door blocking
MTS BW06 01 Taster Offen / Geschlossen Driver pushbutton
MTS BW06 23 Taster Offen / Geschlossen Stop request pushbutton
MTS BW06 45 Taster Offen / Geschlossen Pram pushbutton
MTS BW06 67 Türlauf nicht verhindert / Verhindert Door blocking
MTS BW07 01 Taster Offen / Geschlossen Driver pushbutton
MTS BW07 23 Taster Offen / Geschlossen Stop request pushbutton
MTS BW07 45 Taster Offen / Geschlossen Pram pushbutton
MTS BW07 67 Türlauf nicht verhindert / Verhindert Door blocking
MTS BW08 01 Taster Offen / Geschlossen Driver pushbutton
MTS BW08 23 Taster Offen / Geschlossen Stop request pushbutton
MTS BW08 45 Taster Offen / Geschlossen Pram pushbutton
MTS BW08 67 Türlauf nicht verhindert / Verhindert Door blocking
MTS BW09 01 Aktiv / Nicht Aktiv Switch-off of automatic door mechanism
MTS BW09 23 Aktiv / Nicht Aktiv 'Enable pram function' switch
MTS BW09 45 Taster Offen / Geschlossen Driver pushbutton for rear door
MTS BW09 67 V Supply voltage
MTS BW10 01 Ja / Nein 'Vehicle moving' CAN signal
MTS BW21 01 Schalter Offen / Geschlossen Front pressure switch 'open'
MTS BW21 23 Schalter Offen / Geschlossen Rear pressure switch 'open'
MTS BW21 45 Schalter Offen / Geschlossen Front pressure switch 'closed'
MTS BW21 67 Schalter Offen / Geschlossen Rear pressure switch 'closed'
MTS BW22 01 -- Learned number of door drives
MTS BW22 23 Aktiv / Nicht Aktiv 'Pressure wave' status
MTS BW22 45 Aktiv / Nicht Aktiv Status of hold-open device
MTS BW22 67 Vorhanden / Nicht Vorhanden 'Door blocking' input signal
MTS BW23 01 Taster Offen / Geschlossen Workshop pushbutton
MTS BW23 23 Schalter Offen / Geschlossen 'Emergency operation' switch
MTS BW23 45 Vorhanden / Nicht Vorhanden 'Automatic mode' input signal
MTS BW24 01 Vorhanden / Nicht Vorhanden 'Stop request' input signal
MTS BW24 23 Vorhanden / Nicht Vorhanden 'Pram' input signal
MTS BW25 01 Vorhanden / Nicht Vorhanden 'Stop request' status
MTS BW25 23 Aktiv / Nicht Aktiv Pram function
MTS BW25 45 Aktiv / Nicht Aktiv Automatic function
MTS BW26 01 Gespeichert / Nicht Gespeichert Opening pulse from driver pushbutton
MTS BW26 23 Gespeichert / Nicht Gespeichert Opening pulse from stop request
MTS BW26 45 Gespeichert / Nicht Gespeichert Opening pulse by means of pram request
MTS BW41 01 Schalter Offen / Geschlossen Front pressure switch 'open'
MTS BW41 23 Schalter Offen / Geschlossen Rear pressure switch 'open'
MTS BW41 45 Schalter Offen / Geschlossen Front pressure switch 'closed'
MTS BW41 67 Schalter Offen / Geschlossen Rear pressure switch 'closed'
MTS BW42 01 -- Learned number of door drives
MTS BW42 23 Aktiv / Nicht Aktiv 'Pressure wave' status
MTS BW42 45 Aktiv / Nicht Aktiv Status of hold-open device
MTS BW42 67 Vorhanden / Nicht Vorhanden 'Door blocking' input signal
MTS BW43 01 Taster Offen / Geschlossen Workshop pushbutton
MTS BW43 23 Schalter Offen / Geschlossen 'Emergency operation' switch
MTS BW43 45 Vorhanden / Nicht Vorhanden 'Automatic mode' input signal
MTS BW44 01 Vorhanden / Nicht Vorhanden 'Stop request' input signal
MTS BW44 23 Vorhanden / Nicht Vorhanden 'Pram' input signal
MTS BW45 01 Vorhanden / Nicht Vorhanden 'Stop request' status
MTS BW45 23 Aktiv / Nicht Aktiv Pram function
MTS BW45 45 Aktiv / Nicht Aktiv Automatic function
MTS BW46 01 Gespeichert / Nicht Gespeichert Opening pulse from driver pushbutton
MTS BW46 23 Gespeichert / Nicht Gespeichert Opening pulse from stop request
MTS BW46 45 Gespeichert / Nicht Gespeichert Opening pulse by means of pram request
MTS BW61 01 Schalter Offen / Geschlossen Front pressure switch 'open'
MTS BW61 23 Schalter Offen / Geschlossen Rear pressure switch 'open'
MTS BW61 45 Schalter Offen / Geschlossen Front pressure switch 'closed'
MTS BW61 67 Schalter Offen / Geschlossen Rear pressure switch 'closed'
MTS BW62 01 -- Learned number of door drives
MTS BW62 23 Aktiv / Nicht Aktiv 'Pressure wave' status
MTS BW62 45 Aktiv / Nicht Aktiv Status of hold-open device
MTS BW62 67 Vorhanden / Nicht Vorhanden 'Door blocking' input signal
MTS BW63 01 Taster Offen / Geschlossen Workshop pushbutton
MTS BW63 23 Schalter Offen / Geschlossen 'Emergency operation' switch
MTS BW63 45 Vorhanden / Nicht Vorhanden 'Automatic mode' input signal
MTS BW64 01 Vorhanden / Nicht Vorhanden 'Stop request' input signal
MTS BW64 23 Vorhanden / Nicht Vorhanden 'Pram' input signal
MTS BW65 01 Vorhanden / Nicht Vorhanden 'Stop request' status
MTS BW65 23 Aktiv / Nicht Aktiv Pram function
MTS BW65 45 Aktiv / Nicht Aktiv Automatic function
MTS BW66 01 Gespeichert / Nicht Gespeichert Opening pulse from driver pushbutton
MTS BW66 23 Gespeichert / Nicht Gespeichert Opening pulse from stop request
MTS BW66 45 Gespeichert / Nicht Gespeichert Opening pulse by means of pram request
MTS BW81 01 Schalter Offen / Geschlossen Front pressure switch 'open'
MTS BW81 23 Schalter Offen / Geschlossen Rear pressure switch 'open'
MTS BW81 45 Schalter Offen / Geschlossen Front pressure switch 'closed'
MTS BW81 67 Schalter Offen / Geschlossen Rear pressure switch 'closed'
MTS BW82 01 -- Learned number of door drives
MTS BW82 23 Aktiv / Nicht Aktiv 'Pressure wave' status
MTS BW82 45 Aktiv / Nicht Aktiv Status of hold-open device
MTS BW82 67 Vorhanden / Nicht Vorhanden 'Door blocking' input signal
MTS BW83 01 Taster Offen / Geschlossen Workshop pushbutton
MTS BW83 23 Schalter Offen / Geschlossen 'Emergency operation' switch
MTS BW83 45 Vorhanden / Nicht Vorhanden 'Automatic mode' input signal
MTS BW84 01 Vorhanden / Nicht Vorhanden 'Stop request' input signal
MTS BW84 23 Vorhanden / Nicht Vorhanden 'Pram' input signal
MTS BW85 01 Vorhanden / Nicht Vorhanden 'Stop request' status
MTS BW85 23 Aktiv / Nicht Aktiv Pram function
MTS BW85 45 Aktiv / Nicht Aktiv Automatic function
MTS BW86 01 Gespeichert / Nicht Gespeichert Opening pulse from driver pushbutton
MTS BW86 23 Gespeichert / Nicht Gespeichert Opening pulse from stop request
MTS BW86 45 Gespeichert / Nicht Gespeichert Opening pulse by means of pram request
MTS BW101 01 Schalter Offen / Geschlossen Front pressure switch 'open'
MTS BW101 23 Schalter Offen / Geschlossen Rear pressure switch 'open'
MTS BW101 45 Schalter Offen / Geschlossen Front pressure switch 'closed'
MTS BW101 67 Schalter Offen / Geschlossen Rear pressure switch 'closed'
MTS BW102 01 -- Learned number of door drives
MTS BW102 23 Aktiv / Nicht Aktiv 'Pressure wave' status
MTS BW102 45 Aktiv / Nicht Aktiv Status of hold-open device
MTS BW102 67 Vorhanden / Nicht Vorhanden 'Door blocking' input signal
MTS BW103 01 Taster Offen / Geschlossen Workshop pushbutton
MTS BW103 23 Schalter Offen / Geschlossen 'Emergency operation' switch
MTS BW103 45 Vorhanden / Nicht Vorhanden 'Automatic mode' input signal
MTS BW104 01 Vorhanden / Nicht Vorhanden 'Stop request' input signal
MTS BW104 23 Vorhanden / Nicht Vorhanden 'Pram' input signal
MTS BW105 01 Vorhanden / Nicht Vorhanden 'Stop request' status
MTS BW105 23 Aktiv / Nicht Aktiv Pram function
MTS BW105 45 Aktiv / Nicht Aktiv Automatic function
MTS BW106 01 Gespeichert / Nicht Gespeichert Opening pulse from driver pushbutton
MTS BW106 23 Gespeichert / Nicht Gespeichert Opening pulse from stop request
MTS BW106 45 Gespeichert / Nicht Gespeichert Opening pulse by means of pram request