________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________ ________________
SHB102B   SHB102B - Schuetzeinheit Hochvoltbatterie (18A16)
00F0F1 Global soc 0%
00F9EC Not able to keep main contactor closed
00FAEC Target voltage limit reaches (during floating)
01F9EC Not able to keep main contactor opened
02F9EC Not able to keep contactor precharge opened
0C200B ECU board over temperature
10F0F2 Warning isolation monitoring value close to limit alarm (-pole)
10F9EC Not able to open main contactor
11F0F2 Warning isolation monitoring value close to limit alarm (+pole)
11F9EC Not able to open precharge contactor
12F0E1 Critical isolation monitoring value under limit alarm (-pole)
13F0E1 Critical isolation monitoring value under limit alarm (+pole)
20F0F1 ECU power supply undervoltage
21F0EF ECU power supply overvoltage
22F9E1 Voltage issue during precharge
23F9EC Precharge error
24F9EC Precharge cooldown
25F9EC Not able to close main contactor
26F9EC Not able to close precharge contactor
28F9EC Precharge without voltage
29F9EC No HV entering heating mode
2AF9EC Closing error on Main contactor on Slave SHB
2BF9EC Closing error on contactor Precharge Slave
30F9EC CAN communication loss with BMS GW
31F0EC CAN communication loss with HVBB2
31F9EC CAN communication loss with all HVBB
32F0EC CAN communication loss with HVBB3
32F9EC CAN communication loss with SHB2
33F0EC CAN communication loss with HVBB4
34F0EC CAN communication loss with HVBB5
35F0EC CAN communication loss with HVBB6
36F0EC CAN communication loss with HVBB7
37F0EC CAN communication loss with HVBB8
38F0EC CAN communication loss with HVBB9
39F0EC CAN communication loss with HVBB10
3AF0EC CAN communication lost with HVBB11
3BF0EC CAN communication lost with HVBB12
3CF0EC CAN communication lost with HVBB13
3DF0EC CAN communication lost with HVBB14
3EF0EC CAN communication lost with HVBB15
40F0EC Voltage between (at least) 2 HVBB above limit
40F9E4 Critical ECU power supply undervoltage alarm
41F9E3 Critical ECU power supply overrvoltage alarm
42F9EC Loss of power supply outside idle mode
50F9E3 Signal HV_ENABLE out of range
80F9EC Software safety library Error or Security module Reset
81F9EC Software safety library Error : INIT_FAIL
82F9EC Software safety library Error : SETUP_FAIL
83F9EC Software safety library Error : SWITCH_PHASE_FAIL
84F9EC Software safety library Error : ERR_INJ_FAIL
85F9EC Software safety library Error : EARLY_PRE_RUN_TST_FAIL
86F9EC Software safety library Error : PRE_RUN_TST_FAIL
87F9EC Software safety library Error : RUN_TST_FAIL
88F9EC Software safety library Error : POST_RUN_TST_FAIL
8AF9EC HVBB adressing error (2 HVBB at the same adresse)
8CF9EC SHB adressing issue
91F9EC Evacuation signal coming from HVBB2
92F9EC Evacuation signal coming from HVBB3
93F9EC Evacuation signal coming from HVBB4
94F9EC Evacuation signal coming from HVBB5
95F9EC Evacuation signal coming from HVBB6
96F9EC Evacuation signal coming from HVBB7
97F9EC Evacuation signal coming from HVBB8
98F9EC Evacuation signal coming from HVBB9
99F9EC Evacuation signal coming from HVBB10
9AF9EC Evacuation signal coming from HVBB11
9BF9EC Evacuation signal coming from HVBB12
9CF9EC Evacuation signal coming from HVBB13
9DF9EC Evacuation signal coming from HVBB14
9EF9EC Evacuation signal coming from HVBB15
27F9EC HVBB problem during shutdown transition
51F9F3 HV_ENABLE signal implausible OFF
52F9F3 HV_ENABLE signal implausible ON
60F9EC No HVBB available
89F9EC Wrong HVBB adresse (Standalone)